PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS

Explore the Latest Papers at ASGMT

  • Home
  • |
  • Papers
  • |
  • PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS

Papers by year

Select Year

January 12, 2005

Because of the adverse effects of pulsations on orifice and other types of flow meters there is for many installations, a need to eliminate or decrease the amplitude of pulsations in the piping. This task has been the primary domain of acoustical piping designers who have had both theoretical and practical field experience in such areas. The most common and effective treatment for pulsation control is the design and installation of acoustic filters. However, most filters designed by novices are not effective and are costly to operate because of pressure drop losses. This paper discusses the basic principles and considerations in acoustic filter design. There are many small compressors such as well-head gathering compressors that cannot justify the cost of a thorough acoustic analysis in order to protect the nearby orifice meter from excessive pulsations and accompanying square root error. This paper will make an effort to demonstrate design procedures related to a specific type of acoustic filter to be used to reduce pulsations in most simple metering applications. The specific filter is a symmetrical in-line low pass filter